Aspiration from the vitreous of a non-magnetic foreign body

Hector B. Chawla, Joseph A. Coleiro, Fridbert Jonasson

Research output: Contribution to journalArticlepeer-review

Abstract

A non-magnetic vitreal foreign body was aspirated from over the macula through the pars plana. The surgeon guided a blunt needle towards the foreign body while watching both with the binocular indirect ophthalmoscope. His assistant's tentative suction movements with an attached syringe drew the foreign body up into the needle without risking a retinal perforation. Visual recovery was complete. It is suggested that aspiration might be the procedure of choice for such small visible intraocular fragments.

Original languageEnglish
Pages (from-to)788-789
Number of pages2
JournalBritish Journal of Ophthalmology
Volume62
Issue number11
DOIs
Publication statusPublished - 1978

Fingerprint

Dive into the research topics of 'Aspiration from the vitreous of a non-magnetic foreign body'. Together they form a unique fingerprint.

Cite this